(LO-RAD) - SPECIALIZED SERVICES
We provide services as mentions brelow
LO-RAD RADIOGRAPHIC TECHNIQUE:
The concept is to collimate the radiation beam towards an area of interest. The area of interest is then enclosed with the LO-RAD Mazel Mats. This enclosed system eliminates all unwanted radiation and scatter from the primary beam.
The LO-RAD system when used in conjunction with Selenium 75 will reduce “safe working distance” If used correctly, the system will allow you a 1 – 3 meter barricade and still give you an acceptable reading 7.5 uSv/h.
The clear benefit for the client in decrease in loss of production and down time. Due to the small barricade areas required, the system allows us to carry out radiography continuously for a 24 hours period.
LO-RAD BENEFITS :
- LO-RAD system and technique will be an assistant in achieving earlier start up of plants.
- LO-RAD system will also allowing the client to meet demands and deadlines of shut downs.
- With the LO-RAD system – NO production is lost due to radiography.
- LO-RAD system will eliminate the need to evacuate personnel.
- LO-RAD system will highlight “overhead cost savings” due to NO productive wages being paid.
- Using the LO-RAD system you will NO longer need to plan and manage windows for radiography.
(COMPUTER RADIOGRAPHY TESTING) - SPECIALIZED SERVICES
We provide services as mentions brelow
COMPUTED RADIOGRAPHY TESTING :
Computed Radiography or digital radiography use reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible cost like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems.
But more than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application.
Most operations have data, associated with the test to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurement tools increase the throughput in different kinds of operations.
COMPUTED RADIOGRAPHY TESTING ADVANTAGES:
-
No silver based film or chemicals are required to process film.
-
Reduced film storage cost because images can be stored digitally.
-
Computed radiography often requires fewer retakes due to under-or over-exposure which results in lower overall dose to the personnel that handle it.
-
Image acquisition is much faster-image previews can be available in less than 15 seconds.
-
By adjusting image brightness and/or contrast, a wide range of thickness may be examined in on exposure, unlike conventional film base radiography, which may require a different exposure or multiple film speeds in one exposure to cover wide thickness range in a component.
- Image can be enhancing digitally to aid in interpretation.
- Images can be stored on disk or transmitted for off-site review.
- Ever growing technology makes the CR more affordable than ever today. With chemicals, dark room storage and staff to recognize them, you could own CR for the same monthly cost while being environmentally conscious, depending upon the size of the radiographic operation.